Narishige Pc10 Manual New Review
The unit utilizes a main slider assembly. To pull fine-tipped patch-clamping pipettes, you may need to add or subtract the removable ring weights included in the accessory kit. Installing the Heating Coil
The Narishige PC-10 is a precision instrument designed for a wide range of laboratory applications, including micromanipulation, microinjection, and other delicate procedures. Its design and functionality are geared towards providing researchers with the precision and control needed for successful experimentation. The device's popularity stems from its reliability, ease of use, and the comprehensive guidance provided in its manual.
Automates the transition from a first "thinning" pull to a second final pull for consistent tip geometry. Stabilized Power Supply: narishige pc10 manual new
Narishige PC-10 is a vertical micropipette puller that uses gravity and automated two-stage pulling to create glass needles for microinjection and patch clamping. Tritech Research Key Controls & Components Mode-Selector Knob : Switches between four modes: : Starts single-stage pulling. : Starts two-stage (double) pulling. NO. 1 HEATER / NO. 2 HEATER
Install the desired number of weights. Using all four weights creates a sharper, finer tip; fewer weights create a longer, more gradual taper. Mounting the Glass The unit utilizes a main slider assembly
Store the pulled pipettes in a dust-free, enclosed pipette storage box. 5. Troubleshooting and Maintenance Probable Cause Corrective Action Heater dial set too high or pull weights are too light.
A new manual is not just paperwork—it is a safety device. If your lab still uses a PC-10, print a fresh copy and laminate the calibration page next to the machine. Its design and functionality are geared towards providing
The device uses gravitational force as its pulling mechanism, which can be adjusted through several manual and digital controls:
She ran a test series—a slow aspirate, a fast dispense, a micro-adjust to find the sweet spot between too slow and too violent. The manual’s charts suggested optimal speeds; Lena found them conservative, affectionate. She skimmed “maintenance” and vowed to clean the seals tonight. The manual ended with a quiet paragraph about responsibility: instruments carried memory, and the lab was a place where those memories mattered.
Narishige PC-10 Glass Pipette Puller: Setup, Operation, and Maintenance Manual
Poor contact or broken heater; tighten fixing screws or replace the filament. NARISHIGE GROUP Maintenance Tips